-40%

Cisco WS-C3560C-8PC-S CATALYST 3560C SWITCH POE+ 2XDUAL UPLINK IP BASE

$ 71.27

Availability: 49 in stock
  • Restocking Fee: 20%
  • Condition: It comes with console cables, and power cord and 1 year warranty
  • MPN: WSC3560C8PCS
  • Refund will be given as: Money back or replacement (buyer's choice)
  • Number of LAN Ports: 8
  • Return shipping will be paid by: Seller
  • Model: Cisco WS-C3560C-8PC-S CATALYST 3560C
  • Network Management Type: Fully Managed
  • All returns accepted: Returns Accepted
  • Brand: Cisco
  • Network Connectivity: Wired-Ethernet (RJ-45)
  • Type: Ethernet Switch
  • Item must be returned within: 30 Days
  • Ethernet Technology: Gigabit Ethernet (1000-Mbit/s)

    Description

    Included In this Auction
    Model Number
    :
    WS-C3560C-8PC-S
    Quantity Available: 5(five)
    Quantity: ONE (1)
    Warranty: 1YEAR
    1 Power cord
    1 Console cable
    TEST REPORT
    SHOW ENVIRONMENT  ALL
    Switch#sh env al
    SYSTEM TEMPERATURE is OK
    System Temperature Value: 47 Degree Celsius
    System Temperature State: GREEN
    Yellow Threshold : 80 Degree Celsius
    Red Threshold    : 90 Degree Celsius
    SW  PID                 Serial#     Status           Sys Pwr  PoE Pwr  Watts
    --  ------------------  ----------  ---------------  -------  -------  -----
    1  Built-in
    SHOW FLASH:
    Switch# sh flash:
    Directory of flash:/
    2  drwx         512   Mar 1 1993 00:08:12 +00:00  c3560c405ex-universalk9npe-mz.152-2.E3
    545  -rwx         117   Mar 1 1993 00:19:19 +00:00  info
    546  -rwx        1048   Jan 2 2006 00:01:43 +00:00  multiple-fs
    57931776 bytes total (32169472 bytes free)
    SHOW POST
    Switch#sh post
    Stored system POST messages:
    Switch 1
    ---------
    POST: MA BIST : Begin
    FC 1   MBIST Test Passed.
    DP Sg1 MBIST Test Passed.
    DP Xg1 MBIST Test Passed.
    NI 1   MBIST Test Passed.
    FC 0   MBIST Test Passed.
    DP Sg0 MBIST Test Passed.
    DP Xg0 MBIST Test Passed.
    NI 0   MBIST Test Passed.
    UPB    MBIST Test Passed.
    POST: MA BIST : End, Status Passed
    POST: TCAM BIST : Begin
    POST: TCAM BIST : End, Status Passed
    POST: Inline Power Controller Tests : Begin
    POST: Inline Power Controller Tests : End, Status Passed
    POST: PortASIC Port Loopback Tests : Begin
    POST: PortASIC Port Loopback Tests : End, Status Passed
    POST: PortASIC Macsec Loopback Tests : Begin
    POST: PortASIC Macsec Loopback Tests : End, Status Passed
    SHOW VERSION
    Switch#sh ver
    Cisco IOS Software, C3560C Software (C3560c405ex-UNIVERSALK9NPE-M), Version 15.2(2)E3, RELEASE SOFTWARE (fc3)
    Technical Support:
    Copyright (c) 1986-2015 by Cisco Systems, Inc.
    Compiled Wed 26-Aug-15 11:39 by prod_rel_team
    ROM: Bootstrap program is C3560C boot loader
    BOOTLDR: C3560C Boot Loader (C3560C-HBOOT-M) Version 12.2(55r)EX1, RELEASE SOFTWARE (fc1)
    Switch uptime is 2 minutes
    System returned to ROM by power-on
    System image file is "flash:/c3560c405ex-universalk9npe-mz.152-2.E3/c3560c405ex-universalk9npe-mz.152-2.E3.bin"
    Last reload reason: Unknown reason
    This product contains cryptographic features and is subject to United
    States and local country laws governing import, export, transfer and
    use. Delivery of Cisco cryptographic products does not imply
    third-party authority to import, export, distribute or use encryption.
    Importers, exporters, distributors and users are responsible for
    compliance with U.S. and local country laws. By using this product you
    agree to comply with applicable laws and regulations. If you are unable
    to comply with U.S. and local laws, return this product immediately.
    A summary of U.S. laws governing Cisco cryptographic products may be found at:
    License Level: ipbase
    License Type: Permanent
    Next reload license Level: ipbase
    cisco WS-C3560CG-8PC-S (PowerPC) processor (revision A0) with 131072K bytes of memory.
    Processor board ID FOCxxxxxx
    Last reset from power-on
    1 Virtual Ethernet interface
    10 Gigabit Ethernet interfaces
    The password-recovery mechanism is enabled.
    512K bytes of flash-simulated non-volatile configuration memory.
    Base ethernet MAC Address       : B8:62:1F:B8:D5:80
    Motherboard assembly number     : 73-13272-04
    Power supply part number        : 341-0407-01
    Motherboard serial number       : FOC15235GDH
    Power supply serial number      : LIT15170D1E
    Model revision number           : A0
    Motherboard revision number     : A0
    Model number                    : WS-C3560CG-8PC-S
    System serial number            : FOCxxxxxxx
    Top Assembly Part Number        : 800-33676-01
    Top Assembly Revision Number    : A0
    Version ID                      : V01
    CLEI Code Number                : CMMD900ARA
    Hardware Board Revision Number  : 0x00
    Switch Ports Model                     SW Version            SW Image
    ------ ----- -----                     ----------            ----------
    *    1 10    WS-C3560CG-8PC-S          15.2(2)E3             C3560c405ex-UNIVERSALK9NP
    Configuration register is 0xF
    Switch#
    LOOP-BACK
    PORT
    TEST
    (TESTED WITH RJ-45 CROSSOVER CABLES)
    Switch>
    Mar 30 01:29:34.291: %ILPOWER-7-DETECT: Interface Fa0/1: Power Device detected: IEEE PD
    Mar 30 01:29:35.121: %ILPOWER-5-POWER_GRANTED: Interface Fa0/1: Power granted
    Mar 30 01:29:38.628: %LINK-3-UPDOWN: Interface FastEthernet0/1, changed state to up
    Mar 30 01:29:39.634: %LINEPROTO-5-UPDOWN: Line protocol on Interface FastEthernet0/1, changed state to up
    Mar 30 01:29:40.909: %LINEPROTO-5-UPDOWN: Line protocol on Interface FastEthernet0/1, changed state to down
    Mar 30 01:29:41.908: %LINK-3-UPDOWN: Interface FastEthernet0/1, changed state to down
    Mar 30 01:29:46.068: %LINK-3-UPDOWN: Interface FastEthernet0/1, changed state to up
    Mar 30 01:29:47.075: %LINEPROTO-5-UPDOWN: Line protocol on Interface FastEthernet0/1, changed state to up
    Mar 30 01:29:56.537: %ILPOWER-5-IEEE_DISCONNECT: Interface Fa0/1: PD removed
    Mar 30 01:29:57.032: %LINEPROTO-5-UPDOWN: Line protocol on Interface FastEthernet0/1, changed state to down
    Mar 30 01:29:58.031: %LINK-3-UPDOWN: Interface FastEthernet0/1, changed state to down
    Mar 30 01:29:59.658: %ILPOWER-7-DETECT: Interface Fa0/2: Power Device detected: IEEE PD
    Mar 30 01:30:00.438: %ILPOWER-5-POWER_GRANTED: Interface Fa0/2: Power granted
    Mar 30 01:30:04.314: %LINK-3-UPDOWN: Interface FastEthernet0/2, changed state to up
    Mar 30 01:30:07.233: %LINK-3-UPDOWN: Interface FastEthernet0/2, changed state to down
    Mar 30 01:30:11.352: %LINK-3-UPDOWN: Interface FastEthernet0/2, changed state to up
    Mar 30 01:30:12.358: %LINEPROTO-5-UPDOWN: Line protocol on Interface FastEthernet0/2, changed state to up
    Mar 30 01:30:22.483: %ILPOWER-5-IEEE_DISCONNECT: Interface Fa0/2: PD removed
    Mar 30 01:30:22.953: %LINEPROTO-5-UPDOWN: Line protocol on Interface FastEthernet0/2, changed state to down
    Mar 30 01:30:23.951: %LINK-3-UPDOWN: Interface FastEthernet0/2, changed state to down
    Mar 30 01:30:26.082: %ILPOWER-7-DETECT: Interface Fa0/3: Power Device detected: IEEE PD
    Mar 30 01:30:29.505: %ILPOWER-5-POWER_GRANTED: Interface Fa0/3: Power granted
    Mar 30 01:30:33.313: %LINK-3-UPDOWN: Interface FastEthernet0/3, changed state to up
    Mar 30 01:30:37.272: %LINEPROTO-5-UPDOWN: Line protocol on Interface FastEthernet0/3, changed state to up
    Mar 30 01:30:54.746: %ILPOWER-5-IEEE_DISCONNECT: Interface Fa0/3: PD removed
    Mar 30 01:30:55.216: %LINEPROTO-5-UPDOWN: Line protocol on Interface FastEthernet0/3, changed state to down
    Mar 30 01:30:56.214: %LINK-3-UPDOWN: Interface FastEthernet0/3, changed state to down
    Mar 30 01:30:56.986: %ILPOWER-7-DETECT: Interface Fa0/4: Power Device detected: IEEE PD
    Mar 30 01:30:57.766: %ILPOWER-5-POWER_GRANTED: Interface Fa0/4: Power granted
    Mar 30 01:31:01.574: %LINK-3-UPDOWN: Interface FastEthernet0/4, changed state to up
    Mar 30 01:31:02.975: %LINK-3-UPDOWN: Interface GigabitEthernet0/1, changed state to up
    Mar 30 01:31:03.982: %LINEPROTO-5-UPDOWN: Line protocol on Interface GigabitEthernet0/1, changed state to up
    Mar 30 01:31:05.508: %LINEPROTO-5-UPDOWN: Line protocol on Interface FastEthernet0/4, changed state to up
    Mar 30 01:31:06.943: %LINEPROTO-5-UPDOWN: Line protocol on Interface GigabitEthernet0/1, changed state to down
    Mar 30 01:31:07.941: %LINK-3-UPDOWN: Interface GigabitEthernet0/1, changed state to down
    Mar 30 01:31:25.826: %ILPOWER-5-IEEE_DISCONNECT: Interface Fa0/4: PD removed
    Mar 30 01:31:26.212: %LINK-3-UPDOWN: Interface GigabitEthernet0/2, changed state to up
    Mar 30 01:31:26.254: %LINK-3-UPDOWN: Interface GigabitEthernet0/1, changed state to up
    Mar 30 01:31:26.371: %LINEPROTO-5-UPDOWN: Line protocol on Interface FastEthernet0/4, changed state to down
    Mar 30 01:31:27.218: %LINEPROTO-5-UPDOWN: Line protocol on Interface GigabitEthernet0/2, changed state to up
    Mar 30 01:31:27.260: %LINEPROTO-5-UPDOWN: Line protocol on Interface GigabitEthernet0/1, changed state to up
    Mar 30 01:31:27.285: %ILPOWER-7-DETECT: Interface Fa0/5: Power Device detected: IEEE PD
    Mar 30 01:31:27.369: %LINK-3-UPDOWN: Interface FastEthernet0/4, changed state to down
    Mar 30 01:31:28.091: %ILPOWER-5-POWER_GRANTED: Interface Fa0/5: Power granted
    Mar 30 01:31:36.689: %LINK-3-UPDOWN: Interface FastEthernet0/5, changed state to up
    Mar 30 01:31:37.696: %LINEPROTO-5-UPDOWN: Line protocol on Interface FastEthernet0/5, changed state to up
    Mar 30 01:31:41.823: %ILPOWER-5-IEEE_DISCONNECT: Interface Fa0/5: PD removed
    Mar 30 01:31:42.326: %LINEPROTO-5-UPDOWN: Line protocol on Interface FastEthernet0/5, changed state to down
    Mar 30 01:31:43.048: %ILPOWER-7-DETECT: Interface Fa0/6: Power Device detected: IEEE PD
    Mar 30 01:31:43.324: %LINK-3-UPDOWN: Interface FastEthernet0/5, changed state to down
    Mar 30 01:31:43.878: %ILPOWER-5-POWER_GRANTED: Interface Fa0/6: Power granted
    Mar 30 01:31:48.383: %LINEPROTO-5-UPDOWN: Line protocol on Interface GigabitEthernet0/2, changed state to down
    Mar 30 01:31:48.802: %LINEPROTO-5-UPDOWN: Line protocol on Interface GigabitEthernet0/1, changed state to down
    Mar 30 01:31:49.373: %LINK-3-UPDOWN: Interface GigabitEthernet0/2, changed state to down
    Mar 30 01:31:49.800: %LINK-3-UPDOWN: Interface GigabitEthernet0/1, changed state to down
    Mar 30 01:31:52.485: %LINK-3-UPDOWN: Interface FastEthernet0/6, changed state to up
    Mar 30 01:31:53.491: %LINEPROTO-5-UPDOWN: Line protocol on Interface FastEthernet0/6, changed state to up
    Mar 30 01:32:22.113: %ILPOWER-5-IEEE_DISCONNECT: Interface Fa0/6: PD removed
    Mar 30 01:32:22.684: %LINEPROTO-5-UPDOWN: Line protocol on Interface FastEthernet0/6, changed state to down
    Mar 30 01:32:23.682: %LINK-3-UPDOWN: Interface FastEthernet0/6, changed state to down
    Mar 30 01:32:24.177: %ILPOWER-7-DETECT: Interface Fa0/7: Power Device detected: IEEE PD
    Mar 30 01:32:24.932: %ILPOWER-5-POWER_GRANTED: Interface Fa0/7: Power granted
    Mar 30 01:32:33.765: %LINK-3-UPDOWN: Interface FastEthernet0/7, changed state to up
    Mar 30 01:32:34.772: %LINEPROTO-5-UPDOWN: Line protocol on Interface FastEthernet0/7, changed state to up
    Mar 30 01:33:31.344: %ILPOWER-5-IEEE_DISCONNECT: Interface Fa0/7: PD removed
    Mar 30 01:33:31.831: %LINEPROTO-5-UPDOWN: Line protocol on Interface FastEthernet0/7, changed state to down
    Mar 30 01:33:32.829: %LINK-3-UPDOWN: Interface FastEthernet0/7, changed state to down
    Mar 30 01:33:33.660: %ILPOWER-7-DETECT: Interface Fa0/8: Power Device detected: IEEE PD
    Mar 30 01:33:34.465: %ILPOWER-5-POWER_GRANTED: Interface Fa0/8: Power granted
    Mar 30 01:33:43.139: %LINK-3-UPDOWN: Interface FastEthernet0/8, changed state to up
    Mar 30 01:33:44.145: %LINEPROTO-5-UPDOWN: Line protocol on Interface FastEthernet0/8, changed state to up
    SFP & RJ-45 GIGABYTE PORTS
    (TESTED WITH GLC-SX-MM FIBER OPTIC CABLES)
    Switch#
    Nov 16 01:46:46.499: %PHY-5-TRANSCEIVERINSERTED: Slot=1 Port=11: Transceiver has been inserted
    Nov 16 01:46:48.508: %LINK-3-UPDOWN: Interface GigabitEthernet0/11, changed state to up
    Nov 16 01:46:49.508: %LINEPROTO-5-UPDOWN: Line protocol on Interface GigabitEthernet0/11, changed state to up
    Nov 16 01:47:11.182: %LINEPROTO-5-UPDOWN: Line protocol on Interface GigabitEthernet0/11, changed state to down
    Nov 16 01:47:12.185: %LINK-3-UPDOWN: Interface GigabitEthernet0/11, changed state to down
    Nov 16 01:47:14.961: %PHY-5-TRANSCEIVERREMOVED: Slot=1 Port=11: Transceiver has been removed
    Nov 16 01:47:18.907: %PHY-5-TRANSCEIVERINSERTED: Slot=1 Port=12: Transceiver has been inserted
    Nov 16 01:47:22.797: %LINK-3-UPDOWN: Interface GigabitEthernet0/12, changed state to up
    Nov 16 01:47:23.800: %LINEPROTO-5-UPDOWN: Line protocol on Interface GigabitEthernet0/12, changed state to up
    Nov 16 01:47:30.930: %LINEPROTO-5-UPDOWN: Line protocol on Interface GigabitEthernet0/12, changed state to down
    Nov 16 01:47:31.930: %LINK-3-UPDOWN: Interface GigabitEthernet0/12, changed state to down
    Nov 16 01:47:33.401: %PHY-5-TRANSCEIVERREMOVED: Slot=1 Port=12: Transceiver has been removed
    **NOTE FOR BUYER**
    If you buyer has any problem with product purchase, please contact us immediately we will resolve it quickly, please don't leave OPEN CASE on ebay or leave Negative feedback before contact us.